Cobham - Thrane

Note: The FBB Tracker is not needed to track these devices, with the exception of the Sailor 150, Explorer 325 and Explorer 300 when background IP/data is also needed.

Firmware versions that support tracking

  • Sailor 500
    • All firmware versions
  • Sailor 250
    • All firmware versions
  • Sailor 150
    • IMPORTANT FIRMWARE UPDATE: Firmware version 1.21 and higher support built in tracking. Allow multiple PDP contexts on SAILOR 150
    • All firmware versions with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.
  • Explorer 727
    • Firmware 1.13 and higher
  • Explorer 325
    • IMPORTANT FIRMWARE UPDATE: Firmware version 1.21 and higher support built in tracking. Allow multiple PDP contexts on EXPLORER 325
    • Firmware 1.13 and higher with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.
  • Explorer 710
    • Firmware 1.05 and higher
  • Explorer 700
    • Firmware 3.07 and higher
  • Explorer 500
    • Firmware 3.03 and higher
  • Explorer 300
    • IMPORTANT FIRMWARE UPDATE: Firmware version 3.04 and higher support built in tracking. Allow multiple PDP contexts on EXPLORER 300
    • Firmware 3.03 and higher with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.

Configuration

Step 1: Logging Into Your Device

IMPORTANT: You must upgrade to firmware version 1.13 or greater to support this feature

Login to http://192.168.0.01 on the same network as your Fleet Broadband

  • Click on “Settings”

  • Click on “LAN”

  • Click on “Network User Groups”

  • Enter the following: Username: admin Password: 1234

  • Press “Login”

Step 2: Configure Settings

  • Click on “Edit” next to “Default group”

  • Change “Automatic Activation” to “Enabled”

  • Press “Apply”

  • Click on the “Tracking” tab under “Settings” in the menu.

  • Enter the follow information under “SERVER CONNECTION” For “APN”, select “SIM default”

Server IP Address 66.165.183.84
Server Port 7474
Client Port 7475
Encryption Key 82738287465721050827674352518283
  • Under “POSITION REPORTS”, select the “Extended” option

  • For “INTERNAL REPORT”, select “Enabled” and enter 15 minutes

  • For “DISTANCE REPORT”, select “Enabled”, enter 100 for “When moved” and a time of 5 minutes is recommended for “Max one report per”

  • Press “Apply”